How to Configure Aix NIM Server

How to configure Aix NIM Server

Master (NIM Master): NIM master one and only in a NIM environment it has the permission to run the commands remotely on NIM Clients. The NIM master has all the NIM resources Client (NIM Client): NIM Client is nothing but any standalone machine or LPAR in the NIM environment. client use the resources that reside on the NIM master to perform the software maintenance, backup etc.., SPOT (NIM Spot): The Shared product Object Tree (SPOT) is a fundamental resource in the NIM environment. A spot provide the /usr file system…

Read More

IBM Power Linux Features and Supported commands

RHEL Power Linux Features and Commands

Features for Open Power Linux (RHEL Power Linux) : Nowadays IBM Power system hardware’s supporting Red Hat Enterprise Linux operating systems using IBM POWER8 processors . We can easily install and configure Rhel 7.1 Little Endian and later edition on IBM Power8 Hardware’s. currently supported only KVM guest Feature’s under Red Hat Enteprise Virtualization for Power systems. Supported architecture code is ppc64le and kernel type is 64 bit kernel. Packages available as per examples : gcc-4.8.3-9.ael7b.ppc64le.rpm.   Features for Power8 Processor & Systems : Power8 has the best Memory &…

Read More

PowerHA SystemMirror 6.1 to 7.1.3 Snapshot Migration

PowerHA SystemMirror 6.1 to 7.1.3 Snapshot Migration

Snapshot Migration From PowerHA v6.1 to v7.1.3 * Whenever we are going to perform PowerHA SystemMirror snapshot migration from 6.1 to 7.1.3. * We have to full fill the PowerHA SystemMirror migration prerequisites. * This document will be going to explain PowerHA SystemMirror snapshot migration. * First we are going discuss about PowerHA SystemMirror snapshot migration prerequisites. Snapshot Migration: * This is not real cluster concept migration. Why because customer would remove the previous version of PowerHA SystemMirror and install the new version of PowerHA SystemMirror 7.1.3.0. * Then configure…

Read More

COE 344 COMPUTER NETWORKS VIDEO TUTORIAL

COE 344 COMPUTER NETWORKS VIDEO TUTORIALS

COE 344 COMPUTER NETWORKS (3-3-4) VIDEO TUTORIAL This course will be taught using TCP/IP top-down approach. Topics covered include introduction to computer networks. Application layer design issues and protocols are discussed. Then, Transport layer design issues, protocols as well as congestion control mechanisms are presented. Socket programming is explained. An in-depth analysis is presented of the Network layer design issues, and inter-networking. MAC layer design issues and protocols are presented. Finally, multimedia network applications are explored.

Read More

Rshexec: cannot connect to node NODE1

rshexec cannot connect to node NODE1

rshexec: cannot connect to node NODE1 * Normally this kind of error we are facing at the time of HACMP Cluster synchronize. * If suppose we are not resolving this issue, cluster resource groups will be going to error mode. * We will not able to solve the error resource groups. Error Message: NODE1:# smitty hacmp -> Extended Configuration -> Extended Verification and Synchronization rshexec: cannot connect to node NODE1 Could not run clfilecollection -u on node NODE1. rshexec: cannot connect to node NODE2 Could not run clfilecollection -u on…

Read More

Clmigcheck utility rshexec cannot connect to node NODE1

ERROR: Internode communication failed, check the clcomd.log file for more information.

ERROR: Internode communication failed, check the clcomd.log file for more information. * Normally this kind of error we are facing at the time PowerHA systemMirror migration Prerequisites. * PowerHA systemMirror clmigcheck utility deducting this kind of errors. * If suppose we are not resolving this issue, we will not able to perform PowerHA SystemMirror 6.1 to 7.1 Rolling or Snapshot migration. * We can identify clmigcheck detailed output on /tmp/clmigcheck/clmigcheck.log Error Message: NODE2:# clmigcheck Saving the existing log, “/tmp/clmigcheck/clmigcheck.log”, to “/tmp/clmigcheck/clmigcheck.log.20160324_1942”. # ## One or more possible problems have been…

Read More

ERROR: exactly one “hosts” entry is required in /etc/netsvc.conf

ERROR: exactly one “hosts” entry is required in /etc/netsvc.conf

ERROR: exactly one “hosts” entry is required in /etc/netsvc.conf * Normally this kind of error we are facing at the time PowerHA systemMirror migration Prerequisites. * PowerHA systemMirror clmigcheck utility deducting this kind of errors. * If suppose we are not resolving this issue, we will not able to perform PowerHA SystemMirror 6.1 to 7.1 Rolling or Snapshot migration. Error Message: NODE1:# clmigcheck ## One or more possible problems have been detected: ERROR: exactly one “hosts” entry is required in /etc/netsvc.conf on node “NODE1”. A value such as the following…

Read More